RadiForce GX540 | EIZO
RadiForceGX540
- Features
- Specifications
- Documents
- Graphics Boards
- QC Software & Tools Accessories
Optimum Breast Screening Monitor
The RadiForce GX540 has obtained FDA 510(k) clearance by the U.S. Food and Drug Administration for breast tomosynthesis and mammography. This ensures that the monitor is capable of displaying detailed breast screening images where high performance is essential.
Breast Tomosynthesis |
Mammography |
View Mammography Images Clearly
5 megapixel monitors allow you to see smaller details that are essential in digital mammography. The high resolution retains important information to prevent decreased image quality and pixelation that occur when viewing at a lower resolution.
Easily Distinguish Subtle Tones
To detect the smallest structures, the monitor offers a high contrast ratio to accurately render the finer details. The deeper black levels distinguish similar shades of gray for sharper monochrome image reproduction.
Low Contrast Image | High Contrast Image |
Bring Out the Finest Details
Thanks to a pixel pitch of just 0.165 mm, the monitor offers exceptionally high brightness levels and a wide aperture ratio to bring out the finest details with a smooth, clear representation.
Pixel Size Comparison
Make the Precise Diagnosis
EIZO carefully measures and sets each and every grayscale tone to create a monitor compliant with DICOM Part 14. This ensures the most consistent shading possible, allowing you to make the most accurate diagnosis.
Manage Effortless Quality Control
An Integrated Front Sensor (IFS) housed within the front bezel measures brightness and grayscale tones and calibrates to the DICOM Part 14 standard. The hands-free IFS performs quality control tasks and does not interfere with the viewing area while in use. This dramatically cuts the workload and maintenance costs needed for maintaining monitor quality control.
Attain Steady Images Across the Screen
The Digital Uniformity Equalizer (DUE) function helps to even out fluctuations in brightness and chroma on different parts of the screen to provide smoother images, a quality typically difficult to attain due to the characteristics of LCD monitors.
Comfortably View from Any Angle
Wide viewing angles allow you to view the screen from the side with minimal color shift, also permitting more than one person to view the monitor comfortably at the same time.
Conserve Energy While Away
The presence sensor feature equipped with some models prompts the monitor to switch to power save mode when it detects you are away, and then resumes normal operation when you return. This ensures that the monitor conserves power when it is not in use, uniting convenience with savings.
Stay Confident with Stable Brightness
EIZO's confidence in its product quality extends to brightness stability which is also covered during the usage time specified in the warranty.
Internal Test Pattern Generator
The internal test pattern generator can be used to visually inspect image quality without attaching external hardware or installing QC software on the mammography workstation. This can be useful during the initial installation or on systems that prohibit users from installing software packages.
Warranty with Safety and Trust
EIZO and its authorized distributors offer a five-year limited warranty.
Ensure Optimal Brightness at All Times
The Ambient Light Tracking (ALT) function with embedded ambient light sensor available with the GX540 continuously checks the lighting conditions of the room and automatically optimizes the monitor's brightness and grayscale tone to DICOM Part 14. This ensures consistently accurate images at all times.
Maintain the Precision
Perform a simplified calibration compliant with DICOM Part 14 using the bundled RadiCS LE quality control software. RadiCS LE corrects the brightness and grayscale tones of the monitor to maintain image accuracy and consistency over time.
View Accurate Images in Moments
The EIZO-patented drift correction function quickly stabilizes the brightness level of the monitor upon startup or wakeup from sleep mode, giving you the most accurate images quickly ready for viewing. In addition, a sensor measures the backlight brightness and automatically compensates for brightness fluctuations caused by ambient temperature and aging for a consistently stable display.
10-Bit Simultaneous Grayscale Display
10-bit (1,024 tones) simultaneous grayscale display extends grayscale fidelity to the boundaries of human visual perception abilities and helps radiologists discern the finest nuances within an image.
10-bit graphics board and 10-bit viewer software needed for 10-bit display.
Select the Ideal Mode for Modalities
The CAL Switch function allows you to choose various modes for different modalities such as CR, CT, and endoscopy. It can be conveniently accessed using the monitor's front panel buttons to easily switch to optimal image viewing conditions.
Improve Operability
EIZO's highly versatile stand offers tilt, swivel, and a wide height adjustment range, enabling you to use the monitor with greater comfort.
Digital Mammography Monitor Quality Control Standards Compliance
EIZO's easy-to-use RadiCS UX1 quality control tool (sold separately) performs precise calibration conforming to DICOM Part 14 and enables quality control complying with ACR Practice Guideline and other QC standard for digital mammography monitors.
Rest Assured with Medical Qualifications
The monitors meet the strictest medical, safety, and EMC emission standards.
Model Variations |
GX540-CL: Clear Base
GX540-CL-P: Pairing |
---|---|
Cabinet Color | Black |
Panel | |
Type | Monochrome (IPS) |
Backlight | LED |
Size | 54 cm / 21.3" |
Native Resolution | 2048 x 2560 (4:5 aspect ratio) |
Viewable Image Size (H x V) | 337.9 x 422.4 mm |
Pixel Pitch | 0.165 x 0.165 mm |
Grayscale Tones |
10-bit (DisplayPort) : 1,024 from a palette of 16,369 tones
8-bit: 256 from a palette of 16,369 tones |
Viewing Angles (H / V, typical) | 176° / 176° |
Brightness (typical) | 1,200 cd/m2 |
Recommended Brightness for Calibration | 500 cd/m2 |
Contrast Ratio (typical) | 1200:1 |
Response Time (typical) | 25 ms (on / off) |
Video Signals | |
Input Terminals | DVI-D (dual link) x 1, DisplayPort x 1 |
Digital Scanning Frequency (H / V) |
31 - 135 kHz / 24 - 61 Hz
Frame synchronous mode: 24.5 - 25.5 Hz, 49 - 51 Hz |
USB | |
Function | 1 upstream, 2 downstream |
Standard | USB 2.0 |
Power | |
Power Requirements | AC 100 - 120 V, 200 - 240 V: 50 / 60 Hz |
Maximum Power Consumption | 108 W |
Typical Power Consumption | 47 W |
Power Save Mode | Less than 0.7 W |
Power Management | DVI DMPM, DisplayPort 1.1a |
Sensor | Backlight Sensor, Integrated Front Sensor, Presence Sensor, Ambient Light Sensor |
Features & Functions | |
Brightness Stabilization | Yes |
Digital Uniformity Equalizer | Yes |
Preset Modes | CAL Switch |
OSD Languages |
English, German, French, Italian, Japanese, Simplified
Chinese, Spanish, Swedish, Traditional Chinese |
Physical Specifications | |
Net Weight | 11.5 kg |
Net Weight (Without Stand) | 8.8 kg |
Hole Spacing (VESA Standard) | 100 x 100 mm |
Certifications & Standards (Please contact EIZO for the latest information.) | CE (Medical Device Directive), EN60601-1, UL60601-1, CSA C22.2 No. 601-1, IEC60601-1, VCCI-B, FCC-B, Canadian ICES-003-B, C-tick, RoHS, China RoHS, WEEE, CCC, GOST-R |
FDA 510(k) Clearance | Yes (for Breast Tomosynthesis, Mammography, and General Radiography) |
Supplied Accessories (May vary by country. Please contact EIZO for details.) | AC power cord, dual link signal cable (DVI-D - DVI-D), signal cable (DisplayPort - DisplayPort), USB cable, Utility Disk (RadiCS LE, ScreenManager Pro for Medical, user's manual) |
Warranty | Five Years |
Dimension Drawing |
Brochures
Manuals
Please note that you must be a registered user to download RadiForce relevant files. If you have not registered, please continue on to our registration page. If you have forgotten your User ID or Password, please send us an e-mail.
Technical Information
November 14, 2012 |
The Advantages of Medical LCD Monitors with LED Backlights [PDF] This document explains the three advantages of medical image display monitors that utilize an LED backlight. |
- Protect against dust and scratches
- Fit between screen and bezel
- Integrated Front Sensor usable
- Keep your screen free from dust and fingerprints
- Includes pump spray and cloth
Contact EIZO
EIZO Inc.
Address:
5710 Warland Drive, Cypress, California 90630
Telephone:
(+1) 562 431 5011
RadiForce Inquiries
Toll free: (800) 800-5202 ext. 220