Display Both Monochrome and Color
The MX216 is the first MX-Series monitor to include EIZO's Hybrid Gamma PXL function, which automatically distinguishes between monochrome and color images pixel by pixel, creating a hybrid display where each pixel has optimum grayscale. As a result, monochrome images are displayed in the DICOM® Part 14 grayscale, while color images are reproduced corresponding to Gamma 2.2, for improved efficiency when viewing color and monochrome images together.
Visual Assessment
The Kumamoto Chuo Hospital, Japan, have conducted a visual assessment of the Hybrid Gamma PXL function included on the RadiForce monitor. Approximately a 37% improvement was noted when comparing the use of a color monitor with Hybrid Gamma PXL to one without it. In addition, Hybrid Gamma PXL was found to operate equally as well as monochrome monitors with GSDF when displaying monochrome images. See the White Paper "The Advantages of Hybrid Gamma PXL" [PDF] |
|
Space-Saving Design for Clinical EnvironmentCompared to the previous MX215, the monitor's width, height, and depth are reduced by 3.4 mm, 22.7 mm, and 45.5 mm respectively – a total of 23% less space – saving more workspace for other tasks in clinics and other facilities. |
|
Evolve Your Image ReadingAs more image modalities become digitalized, radiologists are viewing an increasing amount of information on their screens. EIZO's unique Work-and-Flow technology alleviates the complexity of the imaging workflow with new functions developed with the radiologist in mind. Users can take advantage of Work-and-Flow features with the monitor and bundled RadiCS LE software. |
Quick and Easy Focus
The MX216 is compatible with EIZO's Point-and-Focus function. With Point-and-Focus, you can quickly select and focus areas of your concern with just your mouse and keyboard. Change the brightness and grayscale tones of these areas to make viewing images easier. |
See more with animation |
Achieve Clarity True to the Source Data
When the pixel aperture ratio is increased to meet long-term brightness stability, a typically unavoidable decline in sharpness occurs. With EIZO's unique Sharpness Recovery technology, the decrease in sharpness (MTF) is restored. This allows you to display an image safely on the monitor that is true to the original source data, even at high brightness levels.
MTF measures numerically how faithfully the panel transfers detail from the original image data for viewing. When Sharpness Recovery is turned on, in the case of a 2 pixel line pair (spatial frequency of 0.926 cycles/mm) the MTF increases by approximately 65%.
Rotate the Monitor According to the Image
After installing the included RadiCS LE quality control software, you can link the Image Rotation Plus function with the monitor's built-in gravity sensor. This enables the screen to automatically switch to either portrait or landscape mode based on the orientation of the monitor.
Hassle-Free Multi-Monitor Configuration
Using the DisplayPort connection, you can drive several monitors in a daisy chain sequence. This allows you to configure a multi-monitor setup without the complicated hassle of excessive cabling.
A graphics board that supports daisy chain is necessary.
Make the Precise Diagnosis |
|
EIZO carefully measures and sets each grayscale tone to create a monitor compliant with DICOM Part 14. Furthermore, at startup or upon wakeup, the EIZO patented drift correction function quickly stabilizes the brightness level and compensates the brightness fluctuations caused by the ambient temperature and the passage of time, allowing medical images to be faithfully reproduced with stable brightness and grayscale. |
|
Manage Effortless Calibration |
|
With the RadiCS LE software (included) and Integrated Front Sensor (IFS) built into the front bezel, you can easily calibrate to DICOM Part 14 without having to mount, run, and remove an external sensor. |
|
Versatile Positioning for Improved Operability
EIZO's highly versatile stand offers tilt, swivel and a wide height adjustment range for greater comfort.
Warranty with Safety and Trust
EIZO and its authorized distributors offer a five-year limited warranty.
Our Contribution to SDGs
As part of its corporate social responsibility (CSR) activities, EIZO is contributing towards the United Nations’ Sustainable Development Goals (SDGs). |
|
Supporting a Healthy LifeStarting with our message “Making Each Life Visual”, we aim to support optimal medical care for each and every individual through accurate diagnosis and treatment afforded by our innovative healthcare technologies.
|
||
Environmentally FriendlyOur healthcare products are designed to promote energy efficiency for reduced power consumption and CO2 emissions, while maintaining the high performance and functionality needed in healthcare. We also implement a responsible after-service recycling system. |
Model Variations | MX216-BK: with stand, black |
---|---|
Panel | |
Type | Color (IPS) |
Backlight | LED |
Size | 54 cm / 21.3" |
Native Resolution | 1200 x 1600 (3:4 aspect ratio) |
Viewable Image Size (H x V) | 324.0 x 432.0 mm |
Pixel Pitch | 0.270 x 0.270 mm |
Display Colors |
10-bit (DisplayPort): 1.07 billion from a palette of 543 billion (13-bit) colors
8-bit: 16.77 million from a palette of 543 billion (13-bit) colors |
Viewing Angles (H / V, typical) | 178° / 178° |
Brightness (typical) | 500 cd/m2 |
Contrast Ratio (typical) | 1500:1 |
Response Time (typical) | 20 ms (black-white-black) |
Video Signals | |
Input Terminals | DisplayPort, DVI-D |
Output Terminals | DisplayPort (daisy chain) |
Digital Scanning Frequency (H / V) | 31 - 100 kHz / 59 - 61 Hz |
USB | |
Upstream | USB 2.0: Type-B |
Downstream | USB 2.0: Type-A x 2 |
Power | |
Power Requirements | AC 100 - 240 V: 50 / 60 Hz |
Typical Power Consumption | 26 W |
Maximum Power Consumption | 55 W |
Power Save Mode | 0.6 W or less |
Sensor | Backlight Sensor, Integrated Front Sensor, Ambient Light Sensor |
Features & Functions | |
Brightness Stabilization | Yes |
Digital Uniformity Equalizer | Yes |
Hybrid Gamma PXL | Yes |
Work-and-Flow | Point-and-Focus |
Preset Modes | CAL Switch (DICOM, CAL1, CAL2, Custom, sRGB, Text) |
OSD Languages | English, German, French, Italian, Japanese, Simplified Chinese, Spanish, Swedish, Traditional Chinese |
Physical Specifications | |
Net Weight | 7.6 kg |
Net Weight (Without Stand) | 4.7 kg |
Hole Spacing (VESA Standard) | 100 x 100 mm |
Certifications & Standards (Please contact EIZO for the latest information.) | CE (Medical Device), EN60601-1, ANSI/AAMI ES60601-1, CSA C22.2 No. 601-1, IEC60601-1, VCCI-B, FCC-B, CAN ICES-3 (B), RCM, RoHS, China RoHS, WEEE, CCC, EAC |
FDA | 510(k) Clearance for General Radiography |
Dedicated Software | |
Monitor Quality Control Software RadiCS | Supported |
Supplied Accessories (May vary by country. Please contact EIZO for details.) | |
Signal Cables | DisplayPort (3 m) |
Others | AC power cord (3 m), USB Type-A - USB Type-B cable (3 m), Utility Disk (RadiCS LE, PDF instructions for use, PDF installation manual), instructions for use |
Warranty | Five Years |
Dimension Drawing |
Brochures
Manuals
Please note that you must be a registered user to download RadiForce relevant files. If you have not registered, please continue on to our registration page*. If you have forgotten your User ID or Password, please send us an e-mail.
* This user registration form is a CRM web marketing tool provided by Tricorn Corporation called KREISEL. By clicking on the form, you will be forwarded to the KREISEL page.
Compatibility
Date | Subject |
---|---|
July 30, 2019 | Abnormal Display Issue on Microsoft Windows 10 May 2019 Update (1903) |
January 23, 2019 | A USB signal transmission error may occur between some PCs and EIZO monitors when using EIZO software. |
- EIZO original driver and bios
- PCI-Express x16
- Daisy chain supported
- EIZO original driver and bios
- PCI-Express x16
- Daisy chain supported
- Quality Control Software
- UX2 Calibration Sensor bundled
- Quality Control External Calibration Sensor
- New user-friendly design
- Protect against dust and scratches
- Fit between screen and bezel
- Integrated Front Sensor usable
- Keep your screen free from dust and fingerprints
- Includes pump spray and cloth